Shop

Infusion Pump 600II
September 11, 2020
Super Deluxe Series – tabletop Vacuum
September 11, 2020
Show all

Creative Medical Superview 12

Superview-12 Features

• 12.1″ high-resolution TFT display with LED backlight

• Arrhythmia analysis and S-T segment measurement

• Protection against defibrillator discharge

• Adult/Pediatric/Neonate measurement modes

• Visual and audible alarm; Networking capability

• Up to 9 waveforms simultaneously display

• 140-hour ECG waveform data storage and recall

• 2000-hour data trends with a graphic and tabular view

• 2000 groups event, ARR and SpO2 storage

• Built-in lithium battery; Touch screen optional

Device info
ECG Input dynamic range ±0.5mVp~±5mVp
HR measuring range 15bpm~350bpm
HR measuring accuracy ±1% or ±2bpm, whichever is greater
Sensitivity selection ×1/4, ×1/2, ×1, ×2, ×4 and Auto
Sweeping speed 6.25, 12.5, 25, 50mm/s
Common-mode rejection ratio (CMRR) ≥105dB (Monitoring mode)
≥89dB (Diagnostic mode)
NIBP Technique Oscillometric
Typical measurement time <30 seconds (typical adult cuff)
Measuring range
Systolic pressure Adult: 40mmHg~275mmHg
Pediatric: 40mmHg~200mmHg
Neonate: 40mmHg~135mmHg
Diastolic pressure Adult: 10mmHg~210mmHg
Pediatric: 10mmHg~150mmHg
Neonate: 10mmHg~95mmHg
Mean arterial pressure Adult: 20mmHg~230mmHg
Pediatric: 20mmHg~165mmHg
Neonate: 20mmHg~110mmHg
Measurement accuracy Maximum mean difference: ±5 mmHg
Maximum standard deviation: 8 mmHg
Measurement mode Manual, Auto, STAT
Automatic measuring intervals 1~480min
Temperature Measuring range 21.0°C~50.0°C
Measuring accuracy ±0.2°C for range from 25.0°C~45.0°C
Respiration Rate Measuring range 0rpm~120rpm
Measuring accuracy ±5% or ±2rpm, whichever is greater
SpO2 SpO2 measuring range 0%~100%
SpO2 measuring accuracy 2% for range from 70% to 100%
PR measuring range Low perfusion performance As low as 0.4%
PR measuring accuracy 0bpm~250bpm
EtCO2(Optional) Measuring accuracy 0mmHg ~ 150mmHg
Measuring range ±2bpm or ±2%, whichever is greater
Dual IBP(Optional) Measuring accuracy -30mmHg ~ 300mmHg
Measuring range ±4mmHg or ±2%, whichever is greater
Cardiac Output(Opional) Measuring range 0.2 ~ 20l/min
Measuring accuracy 0.2l/min or 10%, whichever is greater
Blood Temperature(BT) 23°C ~ 45°C
Injector Temperature(IT) 0°C ~ 20°C
Cerebral State Monitoring(Optional) Measuring range
Cerebral State Index(CSI) 0~100
Burst SuppressionRatio(BS%) 0~100%
Forehead EMG Ratio(EMG%) 0~100%
Measuring accuracy ±2 or ±10%, whichever is greater
Others Power supply 100~240Vac, 50/60Hz
Built-in lithium battery 4400mAh Lithium battery
Display 12.1 inch TFT touch screen
Alarming method Audible-visual alarm
Networking port Ethernet port
Spread the love!..